Mitsubishi-electric WT03939X20 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Do samochodu Mitsubishi-electric WT03939X20. MITSUBISHI ELECTRIC WT03939X20 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 144
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Contents Page
1 Foreword
1.1 Introduction of Maintenance Tools 1
1.2 Required Operating Environment 5
1.3 Installation 7
1.4 Starting and Ending the Application 14
2 Terms for Each Section
2.1 Design of Screen 27
2.2 Operating Method 27
3 On-Line Monitor Operation Method
3.1 On-Line Monitor Screen Transfer 28
3.2 Function Chart 29
3.3 Address Search Method 30
3.4 Main Screen 31
3.5 Function Selection Operations 32
3.6 Connecting Information 32
3.7 Operation Monitor 34
3.8 Malfunction Log 42
3.9 Optional Setting 44
3.10 Operation Control 47
3.11 Free contact of indoor unit 49
3.12 Remote error notification 51
3.13
Setting and Monitoring DIDO/AI/PI Controllers
77
4 Off-Line Monitor Operating Method
4.1 Off-Line Monitor Screen Transfer 113
4.2 Function Chart 114
4.3 Operation Monitor 115
4.4 System Information 119
4.5 Monitoring of Pre-error Data 120
4.6 Function common for each screen 121
4.7 Offline Analyze on Wide area access mode
125
5 File Names 126
6 How to change setting of Firewall
131
7 Troubleshooting 136
8 Trademark and license 143
Before using Maintenance Tools, read this manual thoroughly to ensure correct operation.
WT03939X20
Maintenance Tools
for MN converter & G-50A
- Advanced -
Operating Manual
Mitsubishi Electric Air-conditioner Network System
Przeglądanie stron 0
1 2 3 4 5 6 ... 143 144

Podsumowanie treści

Strona 1 - Maintenance Tools

Contents Page 1 Foreword 1.1 Introduction of Maintenance Tools 1 1.2 Required Operating Environment 5 1.3 Installation

Strona 2 - 1 Foreword

9 (5) After setup is complete, "Database is installed !! Press any key to continue..." appears at the bottom of the screen. Press any butto

Strona 3

99[Interlock operation error: Error report output] When the interlock control with the M-NET device is failed (when no response to the interlock oper

Strona 4

100Select one of the following operations by clicking a radio button. * The pressed (sunken) button shows the currently “Enabled” status. * [DIDO

Strona 5 - 1.1.4 Wide area access mode

101 NOTE: If there are several patterns of the same input channel and interlock operation conditions, the interlock c

Strona 6 - *4 About USB port

1023.13.4.3 Temporary interlock prohibition setting (1) Click [Temporary prohibition]. (2) Temporary interlock prohibition setting sc

Strona 7 - 1.2.2 Required Materials

1033.13.4.4 Saving the interlock control settings on DIDO Controllers (66DC) in CSV format (1) Click [File output] to save the interlock control se

Strona 8 - 1.3 Installation

1043.13.5 Interlock control settings on AI Controllers AI Controllers (PAC-YG63MCA) can control the following items of M-NET devices depending on the

Strona 9

1053.13.5.1 Starting the interlock control settings on AI Controllers The password is needed to make the settings for interlock control. Only the all

Strona 10

106<Output> [Interlock target] The unit address of the interlock target is shown. [Transmission intervals (min.)] As long as the input interloc

Strona 11

107[SC communication error detection: Interlock disable] When the communication error with G(B)-50A occurs, whether to enable or disable the interloc

Strona 12

108 (6) Select the line to be set, and click [Edit]. To copy the preset interlock setting, select the line to be copied, and click [Copy], then sel

Strona 13

101.3.2 Running Maintenance Tool Upgrade The following describes how to upgrade the Maintenance Tool. Step 1) Ending the Maintenance Tool Step 2) U

Strona 14

109 [Interlock target] Select the unit address to be controlled. Select one of the following operations by clicking a radio button. * The pressed (

Strona 15

110 NOTE: If there are several patterns of the same input channel and interlock operation conditions,

Strona 16

1113.13.5.3 Temporary interlock prohibition setting (1) Click [Temporary prohibition]. (2) Temporary interlock prohibition setting sc

Strona 17

1123.13.5.4 Saving the interlock control settings on AI Controllers (63MC) in CSV format (1) Click [File output] to save the interlock control sett

Strona 18

113 4.1 Off-Line Monitor Screen Transfer 4 Off-Line Monitor Operating Method Title Screen (Operation monitor Data list screen) (Operatio

Strona 19 - from [Control Panel]

114 4.2 Function Chart 4.2.1 Operation Monitor Off-Line Analizing -------------------- [Refer to 4.3.1] Monitors and prints about unit data saved i

Strona 20

115 4.3 Operation Monitor * Items Performed Here - Monitors and prints about the System Information and the Operating Data of units saved using the

Strona 21

116 - Click on [Help] and “Explanation of Terminology” and “Operation Method” sub-menus can be selected. [Refer to 3.6 Connecting Information 3.6.2

Strona 22

117 - Clicking "Sampling setting ---" displays Sampling Setting Screen. Set the sampling time (interval) by moving [Scroll bar] or input t

Strona 23

1184.3.3 Check mail *Mail Server Setting In order to provide mail checking to the operation data mail-messaged from G-50A by utilizing Mail communi

Strona 24 - 1.4.5.1 Online Connection

11 1.3.3 Uninstalling the Maintenance Tools The method to uninstall the application of the [Maintenance Tools] once installed is given below. (1) Un

Strona 25

119 4.4 System Information 4.4.1 Off-Line Analyzing (1) Click on to display the data list screen of System Information. (2) Click on

Strona 26 - 1.4.5.2 Offline Analyze

120 4.5 Monitoring of Pre-error Data 4.5.1 Off-Line Analyzing (1) Click on to display the data list screen of Pre-error. (2) Click o

Strona 27

1214.6 Function common for each screen (Filing operation) * Clicking the button of "Monitor Data", "Monitor Date", "Last

Strona 28 - 2 Terms for Each Section

122 (b) Divided (file exceeds 15 MB) 1. [The information for dividing data is acquired] screen appears. 2. After the information for dividing da

Strona 29 - Remote error notification

123 4.6.4 Text Convert (1) Clicking to display Data list screen containing the file desired to edit. (Text conversion can also be ada

Strona 30 - 3.2 Function Chart

124 4.6.6 Right-clicking menu - Right-clicking menu Clicking the right button of the mouse on [Monitor data] displays the pop-up menu as shown on t

Strona 31 - 3.3 Address Search Method

1254.7 Offline Analyze on Wide area access mode The function of the offline mode is mostly equals that of the normal mode, however, the following fu

Strona 32 - 3.4 Main Screen

126 5.1 System Information Data When the system information data saved in the database in "3.4 Main Screen (2)" is exported in "4

Strona 33

127 5.3 Pre-error Data When the pre-error data saved in the database in "3.9.4 Monitoring of Pre-error Data" is exported in "4.6.2 Ex

Strona 34

1285.6 DIDO Controller Monitor Data The data saved in Section "3.13.1 Setting and Monitoring DIDO Controllers (66DC)” is stored in c:¥Program

Strona 35 - 3.7 Operation Monitor

12 (2) Click [Browse] and specify CMS-MNG_Driver folder on the CD-ROM. Then click [OK], and click [Next]. (3) Though the warning shown on th

Strona 36

129(5) Out-of-limit alarm history (Section “3.13.2.6” ) MCTAH_20070214_120559.CSV Extension Monitor Time*1 Fixed (6) Measurement category se

Strona 37

130(6) Power failure/restoration history (Section “3.13.3.7” ) MCPPH_20070214_120559.CSV Extension Monitor Time*1 Fixed (7) Pulse unit (weig

Strona 38 - About LM ADAPTER

131 How to Change Setting of Firewall for Windows XP 1. Introduction When connecting Maintenance Tool through G-50A, normal communication may no

Strona 39 - Unit address(Tens digit)

132 (7) The [Local Area Connection Properties] screen will be displayed. (8) Select the [Advanced] tab. (9) Confirm that the checking col

Strona 40

133 (11) [Advanced Settings] will be displayed. (12) Click the checking column of [Internet Mail Server [SMTP]] within the [Service] tab to af

Strona 41 - 3.7.3 Trend graph

134 On the [Windows Security Alert] screen, if [Keep Blocking] or [Ask Me Later] has been selected, the settings of Firewall should be changed manual

Strona 42 - (3) Ending the graph

135 (11) The [Windows Firewall] screen will be displayed. Confirm that Firewall is being set to [On [recommended]]. Do not affix a check mark to [

Strona 43 - 3.8 Malfunction Log

136 Trouble When Installing or Starting Trouble Cause Repair Cannot install. Install CD-ROM not properly positioned. Properly position Insta

Strona 44

137Trouble with Main Screen Trouble Cause Repair Cannot select function selection buttons. Collecting data about individual units using manual sea

Strona 45 - 3.9 Optional Setting

138Operation Monitor Trouble Trouble Cause Repair The monitor display screen on the operation monitor has red characters. Because of the increased

Strona 46 - 3.9.3 Sending Command

13(6) The window shown on the right appears and "USB Serial Port(CMS-MNG)" installation ends. Click [Finish]. This completes US

Strona 47 - 3.9.5 Date / Time Setting

139Operation Monitor Mail Communication Mode Trouble Trouble Cause Repair Operation monitor mail cannot receive normally. A mail address and SMTP s

Strona 48 - 3.10 Operation Control

140Specific troubles induced by E-mail connection mode Trouble Cause Repair The message of ” Not connectable to mail server.” or “Not connectable t

Strona 49

141Setting and Monitoring DIDO/AI/PI Controllers Trouble Trouble Cause Repair The pulse unit (weight) cannot be set on the PI Controller. The PI

Strona 50

142Off-Line Monitor Trouble Trouble Cause Repair The setting of IP address of POP server is incorrect. Set the correct IP address with Mail Server

Strona 51

143 * MS, Microsoft, Microsoft logo, and Windows are registered trademarks and trade names of Microsoft Corporation. Each company may use as regi

Strona 52

141.4 Starting and Ending the Application 1.4.1 Starting the Maintenance Tool (1) Connect the computer and G-50A(MN Converter) and air conditione

Strona 53

151.4.2 Starting the On-Line Monitor(MN Converter connection) 1.4.2.1 In case for local connection This will be used when online monitoring is ad

Strona 54 - 3.12.2 Design of Screen

16 (3) Initial setting of modem For the modem to be installed at the local side (MN Converter side), initial setting should be applied before co

Strona 55

17 (4) Initiating the remote connection To initiate the remote connection, click on the remote setting screen. The Customer Selection Screen wil

Strona 56

181.4.3 Starting the On-Line Monitor(G-50A connection) * To use the Maintenance Tool via G-50A (Network), license registration for the G-50A to be

Strona 57

1 1.1 Introduction of Maintenance Tools The Maintenance Tools are comprised of the On-Line Monitor and the Off-Line Monitor. The following three

Strona 58

191.4.3.2 In case for remote connection (Dialup) In the case when on line monitoring is applied to local air conditioning system (with G-50A instal

Strona 59

20 1.4.3.3 In case for remote connection (E-mail) In the case when on line monitoring is applied to local air conditioning system (with G-50A insta

Strona 60

21[Entering order] 1) Preparing the Customer folder Pressing displays the input screen of customer name, and then enter the name. The setting c

Strona 61

22 1.4.4 Starting the Off-Line Monitor When offline analysis is adapted to the data collected under ONLINE MODE. (1) Clicking "Offline Analyze

Strona 62

231.4.5.1 Online Connection (1) Clicking “Online Connection (Wide area access mode)”on the section screen of Monitor mode. Last click "

Strona 63 - STATUS/POWER

24 (c) Setting the [Air conditioning system name] 1) Under the state when the [Customer name folder] desired to be set on the air conditioning sys

Strona 64

25(d) Other setting You may select the mail address of Maintenance Tool PC itself and the Com port to be used. * To use the E-mail mode, mail setting

Strona 65

261.4.6 Ending the Maintenance Tool 1.4.6.1 Ending the On-Line Monitor (1) Open the Main Screen. (2) Click on [File] on the menu bar. (3) Click

Strona 66

27 2.1 Design of Screen The design of the screen is shown below. - Title Bar Displays the title of the screen. - Menu Bar Displ

Strona 67

28 3.1 On-Line Monitor Screen Transfer 3 On-Line Monitor Operating Method Title Screen Main ScreenOperation ControlConnecting Information O

Strona 68

2(2) In case for local connection (via USB) (CMS-MNG-E) Connecting PC installed with the Maintenance Tool to M-NET transmission line via MN Converter

Strona 69

29 3.2 Function Chart Connecting Information ----------------------- [Refer to 3.6] This allows monitoring of the indoor units connected to the outd

Strona 70 - 3.12.8 Option settings

303.3 Address Search Method 3.3.1 Address Search Method Selection (1) Start the M-NET Maintenance Tools and the Select The Address Searching Method

Strona 71

31 3.4 Main Screen The operations in 3.3 Address Search Method have made information about the units known. The [Unit Attributes] are displayed on

Strona 72 - (Default = 60 sec.)

32 3.5 Function Selection Operations (1) First, click on the desired [Function Selection Button]. (2) Next, click on the Unit to Operate. (

Strona 73

33 (4)Momentarily, the Connecting Information Screen will appear. (5)Click on to end the Connecting Information Screen. (6)The message

Strona 74

34 3.7 Operation Monitor * Items Performed Here - Monitors the operating condition and operating data of the current units every minute. This info

Strona 75

35 When [Mail communication Mode] is selected, the setting items of mail communication will be displayed. - From: Mail Address Set the mail address

Strona 76

36 (8) Click on to end the Operating Status Monitor Screen. The message “Finish the operation status monitor” will appear. Click on

Strona 77 - 2.0 0.5 2.0

37* About LM ADAPTER Operation Monitor Item Performed Here Operation status of LM ADAPTER, current values of network variable and configration prope

Strona 78

383 Introduction to the screen Display Contents <Function set switch> Set status of function selector switch 0:OFF setting 1

Strona 79

31.1.2 On-Line Monitor(via G-50A) The On-Line Monitor is connected to the unit by the central controller(G-50A) and can monitor such areas as system

Strona 80

39Display Contents <Binding status : nvoOnOff_n> Binding information on operation status output 0:No binding 1:Binding <IC connection

Strona 81 - 3.13.1.3 Output control

403.7.3 Trend graph Clicking at 3.7.2 (2) [GRAPH] displays Trend Graph Screen. (1) Procedure for graphing (a)Click [Option] on the menu b

Strona 82

41 (d) Conducting the "Other setting" With "Other setting," the optional function to facilitate graph observation can be set. Cli

Strona 83

423.8 Malfunction Log * Items Performed Here - The malfunction log of the most recent 10 cases (except operation group SC) 3.8.1 Screen Transfer Ope

Strona 84

43 (5) Click on to end the Malfuncion Log Screen. The message “Close the malfunction log display? ” will be displayed. Click on to en

Strona 85 - (Ch1 only) is used

44 3.9 Optional Setting * Items Performed Here - Self-Diagnosis Monitoring : The self-diagnosis function (LED for service monitor) to be performed

Strona 86

45 3.9.3 Sending Command (1) Click on and the Sending Command Screen will appear. (2) Input M-NET command desired to transmit by c

Strona 87

46 3.9.5 Date / Time Setting (1) Click on . The Date / Time Setting Screen opens and the present time of PC is displayed. * When the

Strona 88

473.10 Operation Control * Items Performed Here - ON / OFF of the unit, the operation mode and setting the temperature can be performed in the same m

Strona 89

48 3.10.3 Screen Functions and Operation(BC Controller) (1) Click on the button corresponding to the valve number you want to change. “0” represents

Strona 90 - *1 S*2 S*2 M

41.1.3 Off-Line Monitor The Off-Line Monitor can display, print information obtained by the On-Line Monitor. In the case of connection monitoring uti

Strona 91

493.11 Free contact of indoor unit * Items Performed Here - When utilizing the [Indoor unit free contact mode] which uses the external input/output o

Strona 92

50 (2) Automatic monitoring To automatically monitor the contact status of indoor units of No.1 ~ 50 repeatedly, select the [Auto monitor] mode. a

Strona 93

513.12 Remote error notification The “Remote error notification" has been located starting from Ver4.20. * Items Performed Here - The MN Conver

Strona 94

523.12.1 Starting of this function (1) Click [Option] in the menu bar and select [Error notification mode] -> [Error notification mode setting/

Strona 95

533.12.2 Design of Screen There are two kinds of following screens to the Error notification mode setting/cancellation screen. (1) Maintenance mode

Strona 96

54The design of the screen is shown below. - (5) Phone line disconnection setting(Inactivity timeout) Specifies how soon

Strona 97 - [ Refer to 3.13.4.1 (4) ]

553.12.3 Selecting remote error notification mode Specify the settings below to enable the remote error notification function on the MN Converter.

Strona 98

56 (4) Enter the MN Converter address. Enter the M-NET address for the MN Converter. You can enter any number between 201 and 250. Ensure that y

Strona 99

57(6) Specify the error codes targeted for notification. You can use this setting to specify which of the errors that occur in air conditioning units

Strona 100

58(8) Select the system information settings. This option selects whether a host system controller is connected in the M-NET system to which the MN

Strona 101

51.2 Required Operating Environment This manual refers to Windows® 2000 as Windows 2000, and Windows® XP as Windows XP. 1.2.1 Hardware Requirements

Strona 102

59(10) Send the settings. Click [Send settings]. When the Settings will be sent. OK? message appears, click [Yes]. Setting begins. When se

Strona 103

603.12.4 Error notification testing After setting the MN Converter to remote error notification mode, run the error notification test to check that n

Strona 104

61 The error messages are shown below. If an error occurs, check the connections, etc. Error message When Test report Error message Meaning/

Strona 105

62 3.12.5 Report log A log of past error notifications is saved in the MN Converter. You can use the Maintenance Tool to view and check the Report l

Strona 106 - is monitored

63The design of the screen is shown below. - (1) Site name Name of the system being monitored [see section 3.12.3 (

Strona 107

64 3.12.5.2 Clearing the Report log (1) Click the [Log clear] button in the Report log screen. (2) Click [Yes]. (3) The Report lo

Strona 108

65(2) Select CSV format and click [OK]. Use , -- Uses a comma (,) as the delimiter in the CSV file. Use ; -- Uses a semicolon (;) as th

Strona 109

663.12.6 Changing the error notification settings (1) Click [Option] in the menu bar and select [Error notification mode] -> [Error no

Strona 110

67 (4) Select System information settings. (5) Click [Send settings]. A confirmation window is displayed. Click [Yes]. Setting begins.

Strona 111

68(9) Click [Close] to close the Error notification mode setting/cancellation screen. 3.12.7 Canceling error notification mode Thi

Strona 112

61.2.2 Required Materials The following materials are needed for operating the Maintenance Tools : (1) In case of routing via MN converter MN Conv

Strona 113

69(3) When setting is completed, the All settings have been cancelled message appears. Click [OK]. The MN Converter switches to maintenance mod

Strona 114 - Title Screen

70 (4) The new settings are applied on the MN Converter and the window shown below appears. Note: If the MN Converter is report

Strona 115 - 4.2 Function Chart

71The various settings are explained below. - (1) Minimum reporting period (mins.) (Default = 10 min.) Set a period betwee

Strona 116 - 4.3 Operation Monitor

72- (3) Redial interval (secs.) (Default = 30 sec.) If the MN Converter dials a notification contact but the contact telephone does not answer,

Strona 117 - 4.3.2 Graph

73The figure below summarizes these settings. [If the notification contact telephone does not answer]

Strona 118

74[If the notification contact telephone answers] (1) Minimum reporting periodError occurred Dial Contact telephon

Strona 119 - 4.3.3 Check mail

753.12.9 Error notification data format The notification data sent from the MN Converter to the remote monitoring PC via the telephone lines is in th

Strona 120 - 4.4 System Information

763.12.10 MN Converter LED display The MN Converter (CMS-MNG-E) has a STATUS LED (yellow) that displays the converter status. The STATUS LE

Strona 121 - 4.5.1 Off-Line Analyzing

773.13 Setting and Monitoring DIDO/AI/PI Controllers The “Setting and Monitoring DIDO/AI/PI Controllers" has been located starting from Ver4.20.

Strona 122 - (Filing operation)

78The function allotment of DIDO Controller, G(B)-50A Web,TG-2000A and Maintenance Tools is as follows. [Note]S:Setting possibility, M:Monitoring on

Strona 123 - 4.6.3 Import

71.3 Installation There are two Maintenance Tool setup methods: Method 1) New setup.(See Section 1.3.1) Method 2) Upgrading with existing setup.(Se

Strona 124 - 4.6.4 Text Convert

79 (5) The current time is monitored, and Date/Time setting screen will appear. (6) Set the current date and time. (7) Click [Send settings]. (8)

Strona 125 - 4.6.6 Right-clicking menu

803.13.1.3 Output control (1) Click [Output control] in the DIDO controller (66DC) input/output status monitoring screen. (2) The curr

Strona 126

813.13.1.4 Monitoring Dip switch setting of DIDO Controllers (1) Click [Option] in the DIDO controller (66DC) input/output status monitoring scre

Strona 127 - 5 File Names

823.13.2 Setting and Monitoring AI Controllers (63MC) AI Controller (PAC-YG63MCA) is capable of measuring the temperature and humidity. Trend displ

Strona 128

83The following settings and monitoring can be made on AI Controllers (PAC-YG63MCA). When G(B)-50A or TG-2000A is connected, the setting must be made

Strona 129

843.13.2.2 Setting for AI Controllers (63MC) (1) Click [Setting contents] in the AI controller (63MC) measurement value monitoring screen.

Strona 130

85 (6) The message ”Settings will be sent. OK?” will appear, click [Yes]. The setting will be applied to the unit. (7) The message ”Settings have be

Strona 131

86 (2) The correction value for Pt100 detection is monitored, and Monitoring of the correction value for Pt100 detection screen will appear. [C

Strona 132

873.13.2.6 Out-of-limit alarm history The history of out-of-limit alarm/alarm-off is displayed. Up to 100 of the latest data can be displayed. (1

Strona 133

883.13.2.7 Measurement category setting history The change history of measurement category (temperature or humidity) is displayed. Up to 10 of the la

Strona 134

8Step 2) Setting up the Maintenance Tools Set up the application of this Maintenance Tools. Please read the guide shown on the screen carefully to pr

Strona 135

893.13.3 Monitoring PI Controllers (60MC) PI Controller (PAC-YG60MCA) counts pulses from a power meter, gas meter, water meter, and calorimeter. The

Strona 136

903.13.3.1 PI Controller (60MC) measurement value Monitor (current value) (1) Click [Option] in the menu bar and select [DIDO/AI/PI] -> [AI/PI s

Strona 137 - 7 Troubleshootin

91(3) Click [Monitor update] to update the measurement values. (4) Click [File output] to save the monitored information as a CSV file. Refer to sec

Strona 138 - Trouble with Main Screen

92 (2) The setting details are monitored, and PI controller (60MC) setting screen will appear. No settings of PI Controller can be made in the Ma

Strona 139 - Malfunction Log Trouble

933.13.3.6 Monitoring Dip switch setting of PI Controllers (1) Click [Option] in the PI controller (60MC) measurement value monitoring screen and

Strona 140 - Trouble Cause Repair

943.13.3.8 Pulse unit (weight) change history (1) Click [Option] in the PI controller (60MC) measurement value monitoring screen and select [Pul

Strona 141

953.13.4 Interlock control settings on DIDO Controllers (66DC) DIDO Controllers (PAC-YG66DCA) can control the following items of M-NET devices or the

Strona 142

963.13.4.1 Starting the interlock control settings on DIDO Controllers The password is needed to make the settings for interlock control. Only the al

Strona 143 - Off-Line Monitor Trouble

973.13.4.2 Interlock control settings on DIDO Controllers (1) Click [Option] in the menu bar and select [DIDO/AI/PI] -> [DIDO/AI interlock setting

Strona 144 - 8 Trademark and license

98<Interlock special condition setting> [Emergency stop receive: Interlock disable] When the emergency stop command is received from G(B)-50A,

Komentarze do niniejszej Instrukcji

Brak uwag