Contents Page 1 Foreword 1.1 Introduction of Maintenance Tools 1 1.2 Required Operating Environment 5 1.3 Installation
9 (5) After setup is complete, "Database is installed !! Press any key to continue..." appears at the bottom of the screen. Press any butto
99[Interlock operation error: Error report output] When the interlock control with the M-NET device is failed (when no response to the interlock oper
100Select one of the following operations by clicking a radio button. * The pressed (sunken) button shows the currently “Enabled” status. * [DIDO
101 NOTE: If there are several patterns of the same input channel and interlock operation conditions, the interlock c
1023.13.4.3 Temporary interlock prohibition setting (1) Click [Temporary prohibition]. (2) Temporary interlock prohibition setting sc
1033.13.4.4 Saving the interlock control settings on DIDO Controllers (66DC) in CSV format (1) Click [File output] to save the interlock control se
1043.13.5 Interlock control settings on AI Controllers AI Controllers (PAC-YG63MCA) can control the following items of M-NET devices depending on the
1053.13.5.1 Starting the interlock control settings on AI Controllers The password is needed to make the settings for interlock control. Only the all
106<Output> [Interlock target] The unit address of the interlock target is shown. [Transmission intervals (min.)] As long as the input interloc
107[SC communication error detection: Interlock disable] When the communication error with G(B)-50A occurs, whether to enable or disable the interloc
108 (6) Select the line to be set, and click [Edit]. To copy the preset interlock setting, select the line to be copied, and click [Copy], then sel
101.3.2 Running Maintenance Tool Upgrade The following describes how to upgrade the Maintenance Tool. Step 1) Ending the Maintenance Tool Step 2) U
109 [Interlock target] Select the unit address to be controlled. Select one of the following operations by clicking a radio button. * The pressed (
110 NOTE: If there are several patterns of the same input channel and interlock operation conditions,
1113.13.5.3 Temporary interlock prohibition setting (1) Click [Temporary prohibition]. (2) Temporary interlock prohibition setting sc
1123.13.5.4 Saving the interlock control settings on AI Controllers (63MC) in CSV format (1) Click [File output] to save the interlock control sett
113 4.1 Off-Line Monitor Screen Transfer 4 Off-Line Monitor Operating Method Title Screen (Operation monitor Data list screen) (Operatio
114 4.2 Function Chart 4.2.1 Operation Monitor Off-Line Analizing -------------------- [Refer to 4.3.1] Monitors and prints about unit data saved i
115 4.3 Operation Monitor * Items Performed Here - Monitors and prints about the System Information and the Operating Data of units saved using the
116 - Click on [Help] and “Explanation of Terminology” and “Operation Method” sub-menus can be selected. [Refer to 3.6 Connecting Information 3.6.2
117 - Clicking "Sampling setting ---" displays Sampling Setting Screen. Set the sampling time (interval) by moving [Scroll bar] or input t
1184.3.3 Check mail *Mail Server Setting In order to provide mail checking to the operation data mail-messaged from G-50A by utilizing Mail communi
11 1.3.3 Uninstalling the Maintenance Tools The method to uninstall the application of the [Maintenance Tools] once installed is given below. (1) Un
119 4.4 System Information 4.4.1 Off-Line Analyzing (1) Click on to display the data list screen of System Information. (2) Click on
120 4.5 Monitoring of Pre-error Data 4.5.1 Off-Line Analyzing (1) Click on to display the data list screen of Pre-error. (2) Click o
1214.6 Function common for each screen (Filing operation) * Clicking the button of "Monitor Data", "Monitor Date", "Last
122 (b) Divided (file exceeds 15 MB) 1. [The information for dividing data is acquired] screen appears. 2. After the information for dividing da
123 4.6.4 Text Convert (1) Clicking to display Data list screen containing the file desired to edit. (Text conversion can also be ada
124 4.6.6 Right-clicking menu - Right-clicking menu Clicking the right button of the mouse on [Monitor data] displays the pop-up menu as shown on t
1254.7 Offline Analyze on Wide area access mode The function of the offline mode is mostly equals that of the normal mode, however, the following fu
126 5.1 System Information Data When the system information data saved in the database in "3.4 Main Screen (2)" is exported in "4
127 5.3 Pre-error Data When the pre-error data saved in the database in "3.9.4 Monitoring of Pre-error Data" is exported in "4.6.2 Ex
1285.6 DIDO Controller Monitor Data The data saved in Section "3.13.1 Setting and Monitoring DIDO Controllers (66DC)” is stored in c:¥Program
12 (2) Click [Browse] and specify CMS-MNG_Driver folder on the CD-ROM. Then click [OK], and click [Next]. (3) Though the warning shown on th
129(5) Out-of-limit alarm history (Section “3.13.2.6” ) MCTAH_20070214_120559.CSV Extension Monitor Time*1 Fixed (6) Measurement category se
130(6) Power failure/restoration history (Section “3.13.3.7” ) MCPPH_20070214_120559.CSV Extension Monitor Time*1 Fixed (7) Pulse unit (weig
131 How to Change Setting of Firewall for Windows XP 1. Introduction When connecting Maintenance Tool through G-50A, normal communication may no
132 (7) The [Local Area Connection Properties] screen will be displayed. (8) Select the [Advanced] tab. (9) Confirm that the checking col
133 (11) [Advanced Settings] will be displayed. (12) Click the checking column of [Internet Mail Server [SMTP]] within the [Service] tab to af
134 On the [Windows Security Alert] screen, if [Keep Blocking] or [Ask Me Later] has been selected, the settings of Firewall should be changed manual
135 (11) The [Windows Firewall] screen will be displayed. Confirm that Firewall is being set to [On [recommended]]. Do not affix a check mark to [
136 Trouble When Installing or Starting Trouble Cause Repair Cannot install. Install CD-ROM not properly positioned. Properly position Insta
137Trouble with Main Screen Trouble Cause Repair Cannot select function selection buttons. Collecting data about individual units using manual sea
138Operation Monitor Trouble Trouble Cause Repair The monitor display screen on the operation monitor has red characters. Because of the increased
13(6) The window shown on the right appears and "USB Serial Port(CMS-MNG)" installation ends. Click [Finish]. This completes US
139Operation Monitor Mail Communication Mode Trouble Trouble Cause Repair Operation monitor mail cannot receive normally. A mail address and SMTP s
140Specific troubles induced by E-mail connection mode Trouble Cause Repair The message of ” Not connectable to mail server.” or “Not connectable t
141Setting and Monitoring DIDO/AI/PI Controllers Trouble Trouble Cause Repair The pulse unit (weight) cannot be set on the PI Controller. The PI
142Off-Line Monitor Trouble Trouble Cause Repair The setting of IP address of POP server is incorrect. Set the correct IP address with Mail Server
143 * MS, Microsoft, Microsoft logo, and Windows are registered trademarks and trade names of Microsoft Corporation. Each company may use as regi
141.4 Starting and Ending the Application 1.4.1 Starting the Maintenance Tool (1) Connect the computer and G-50A(MN Converter) and air conditione
151.4.2 Starting the On-Line Monitor(MN Converter connection) 1.4.2.1 In case for local connection This will be used when online monitoring is ad
16 (3) Initial setting of modem For the modem to be installed at the local side (MN Converter side), initial setting should be applied before co
17 (4) Initiating the remote connection To initiate the remote connection, click on the remote setting screen. The Customer Selection Screen wil
181.4.3 Starting the On-Line Monitor(G-50A connection) * To use the Maintenance Tool via G-50A (Network), license registration for the G-50A to be
1 1.1 Introduction of Maintenance Tools The Maintenance Tools are comprised of the On-Line Monitor and the Off-Line Monitor. The following three
191.4.3.2 In case for remote connection (Dialup) In the case when on line monitoring is applied to local air conditioning system (with G-50A instal
20 1.4.3.3 In case for remote connection (E-mail) In the case when on line monitoring is applied to local air conditioning system (with G-50A insta
21[Entering order] 1) Preparing the Customer folder Pressing displays the input screen of customer name, and then enter the name. The setting c
22 1.4.4 Starting the Off-Line Monitor When offline analysis is adapted to the data collected under ONLINE MODE. (1) Clicking "Offline Analyze
231.4.5.1 Online Connection (1) Clicking “Online Connection (Wide area access mode)”on the section screen of Monitor mode. Last click "
24 (c) Setting the [Air conditioning system name] 1) Under the state when the [Customer name folder] desired to be set on the air conditioning sys
25(d) Other setting You may select the mail address of Maintenance Tool PC itself and the Com port to be used. * To use the E-mail mode, mail setting
261.4.6 Ending the Maintenance Tool 1.4.6.1 Ending the On-Line Monitor (1) Open the Main Screen. (2) Click on [File] on the menu bar. (3) Click
27 2.1 Design of Screen The design of the screen is shown below. - Title Bar Displays the title of the screen. - Menu Bar Displ
28 3.1 On-Line Monitor Screen Transfer 3 On-Line Monitor Operating Method Title Screen Main ScreenOperation ControlConnecting Information O
2(2) In case for local connection (via USB) (CMS-MNG-E) Connecting PC installed with the Maintenance Tool to M-NET transmission line via MN Converter
29 3.2 Function Chart Connecting Information ----------------------- [Refer to 3.6] This allows monitoring of the indoor units connected to the outd
303.3 Address Search Method 3.3.1 Address Search Method Selection (1) Start the M-NET Maintenance Tools and the Select The Address Searching Method
31 3.4 Main Screen The operations in 3.3 Address Search Method have made information about the units known. The [Unit Attributes] are displayed on
32 3.5 Function Selection Operations (1) First, click on the desired [Function Selection Button]. (2) Next, click on the Unit to Operate. (
33 (4)Momentarily, the Connecting Information Screen will appear. (5)Click on to end the Connecting Information Screen. (6)The message
34 3.7 Operation Monitor * Items Performed Here - Monitors the operating condition and operating data of the current units every minute. This info
35 When [Mail communication Mode] is selected, the setting items of mail communication will be displayed. - From: Mail Address Set the mail address
36 (8) Click on to end the Operating Status Monitor Screen. The message “Finish the operation status monitor” will appear. Click on
37* About LM ADAPTER Operation Monitor Item Performed Here Operation status of LM ADAPTER, current values of network variable and configration prope
383 Introduction to the screen Display Contents <Function set switch> Set status of function selector switch 0:OFF setting 1
31.1.2 On-Line Monitor(via G-50A) The On-Line Monitor is connected to the unit by the central controller(G-50A) and can monitor such areas as system
39Display Contents <Binding status : nvoOnOff_n> Binding information on operation status output 0:No binding 1:Binding <IC connection
403.7.3 Trend graph Clicking at 3.7.2 (2) [GRAPH] displays Trend Graph Screen. (1) Procedure for graphing (a)Click [Option] on the menu b
41 (d) Conducting the "Other setting" With "Other setting," the optional function to facilitate graph observation can be set. Cli
423.8 Malfunction Log * Items Performed Here - The malfunction log of the most recent 10 cases (except operation group SC) 3.8.1 Screen Transfer Ope
43 (5) Click on to end the Malfuncion Log Screen. The message “Close the malfunction log display? ” will be displayed. Click on to en
44 3.9 Optional Setting * Items Performed Here - Self-Diagnosis Monitoring : The self-diagnosis function (LED for service monitor) to be performed
45 3.9.3 Sending Command (1) Click on and the Sending Command Screen will appear. (2) Input M-NET command desired to transmit by c
46 3.9.5 Date / Time Setting (1) Click on . The Date / Time Setting Screen opens and the present time of PC is displayed. * When the
473.10 Operation Control * Items Performed Here - ON / OFF of the unit, the operation mode and setting the temperature can be performed in the same m
48 3.10.3 Screen Functions and Operation(BC Controller) (1) Click on the button corresponding to the valve number you want to change. “0” represents
41.1.3 Off-Line Monitor The Off-Line Monitor can display, print information obtained by the On-Line Monitor. In the case of connection monitoring uti
493.11 Free contact of indoor unit * Items Performed Here - When utilizing the [Indoor unit free contact mode] which uses the external input/output o
50 (2) Automatic monitoring To automatically monitor the contact status of indoor units of No.1 ~ 50 repeatedly, select the [Auto monitor] mode. a
513.12 Remote error notification The “Remote error notification" has been located starting from Ver4.20. * Items Performed Here - The MN Conver
523.12.1 Starting of this function (1) Click [Option] in the menu bar and select [Error notification mode] -> [Error notification mode setting/
533.12.2 Design of Screen There are two kinds of following screens to the Error notification mode setting/cancellation screen. (1) Maintenance mode
54The design of the screen is shown below. - (5) Phone line disconnection setting(Inactivity timeout) Specifies how soon
553.12.3 Selecting remote error notification mode Specify the settings below to enable the remote error notification function on the MN Converter.
56 (4) Enter the MN Converter address. Enter the M-NET address for the MN Converter. You can enter any number between 201 and 250. Ensure that y
57(6) Specify the error codes targeted for notification. You can use this setting to specify which of the errors that occur in air conditioning units
58(8) Select the system information settings. This option selects whether a host system controller is connected in the M-NET system to which the MN
51.2 Required Operating Environment This manual refers to Windows® 2000 as Windows 2000, and Windows® XP as Windows XP. 1.2.1 Hardware Requirements
59(10) Send the settings. Click [Send settings]. When the Settings will be sent. OK? message appears, click [Yes]. Setting begins. When se
603.12.4 Error notification testing After setting the MN Converter to remote error notification mode, run the error notification test to check that n
61 The error messages are shown below. If an error occurs, check the connections, etc. Error message When Test report Error message Meaning/
62 3.12.5 Report log A log of past error notifications is saved in the MN Converter. You can use the Maintenance Tool to view and check the Report l
63The design of the screen is shown below. - (1) Site name Name of the system being monitored [see section 3.12.3 (
64 3.12.5.2 Clearing the Report log (1) Click the [Log clear] button in the Report log screen. (2) Click [Yes]. (3) The Report lo
65(2) Select CSV format and click [OK]. Use , -- Uses a comma (,) as the delimiter in the CSV file. Use ; -- Uses a semicolon (;) as th
663.12.6 Changing the error notification settings (1) Click [Option] in the menu bar and select [Error notification mode] -> [Error no
67 (4) Select System information settings. (5) Click [Send settings]. A confirmation window is displayed. Click [Yes]. Setting begins.
68(9) Click [Close] to close the Error notification mode setting/cancellation screen. 3.12.7 Canceling error notification mode Thi
61.2.2 Required Materials The following materials are needed for operating the Maintenance Tools : (1) In case of routing via MN converter MN Conv
69(3) When setting is completed, the All settings have been cancelled message appears. Click [OK]. The MN Converter switches to maintenance mod
70 (4) The new settings are applied on the MN Converter and the window shown below appears. Note: If the MN Converter is report
71The various settings are explained below. - (1) Minimum reporting period (mins.) (Default = 10 min.) Set a period betwee
72- (3) Redial interval (secs.) (Default = 30 sec.) If the MN Converter dials a notification contact but the contact telephone does not answer,
73The figure below summarizes these settings. [If the notification contact telephone does not answer]
74[If the notification contact telephone answers] (1) Minimum reporting periodError occurred Dial Contact telephon
753.12.9 Error notification data format The notification data sent from the MN Converter to the remote monitoring PC via the telephone lines is in th
763.12.10 MN Converter LED display The MN Converter (CMS-MNG-E) has a STATUS LED (yellow) that displays the converter status. The STATUS LE
773.13 Setting and Monitoring DIDO/AI/PI Controllers The “Setting and Monitoring DIDO/AI/PI Controllers" has been located starting from Ver4.20.
78The function allotment of DIDO Controller, G(B)-50A Web,TG-2000A and Maintenance Tools is as follows. [Note]S:Setting possibility, M:Monitoring on
71.3 Installation There are two Maintenance Tool setup methods: Method 1) New setup.(See Section 1.3.1) Method 2) Upgrading with existing setup.(Se
79 (5) The current time is monitored, and Date/Time setting screen will appear. (6) Set the current date and time. (7) Click [Send settings]. (8)
803.13.1.3 Output control (1) Click [Output control] in the DIDO controller (66DC) input/output status monitoring screen. (2) The curr
813.13.1.4 Monitoring Dip switch setting of DIDO Controllers (1) Click [Option] in the DIDO controller (66DC) input/output status monitoring scre
823.13.2 Setting and Monitoring AI Controllers (63MC) AI Controller (PAC-YG63MCA) is capable of measuring the temperature and humidity. Trend displ
83The following settings and monitoring can be made on AI Controllers (PAC-YG63MCA). When G(B)-50A or TG-2000A is connected, the setting must be made
843.13.2.2 Setting for AI Controllers (63MC) (1) Click [Setting contents] in the AI controller (63MC) measurement value monitoring screen.
85 (6) The message ”Settings will be sent. OK?” will appear, click [Yes]. The setting will be applied to the unit. (7) The message ”Settings have be
86 (2) The correction value for Pt100 detection is monitored, and Monitoring of the correction value for Pt100 detection screen will appear. [C
873.13.2.6 Out-of-limit alarm history The history of out-of-limit alarm/alarm-off is displayed. Up to 100 of the latest data can be displayed. (1
883.13.2.7 Measurement category setting history The change history of measurement category (temperature or humidity) is displayed. Up to 10 of the la
8Step 2) Setting up the Maintenance Tools Set up the application of this Maintenance Tools. Please read the guide shown on the screen carefully to pr
893.13.3 Monitoring PI Controllers (60MC) PI Controller (PAC-YG60MCA) counts pulses from a power meter, gas meter, water meter, and calorimeter. The
903.13.3.1 PI Controller (60MC) measurement value Monitor (current value) (1) Click [Option] in the menu bar and select [DIDO/AI/PI] -> [AI/PI s
91(3) Click [Monitor update] to update the measurement values. (4) Click [File output] to save the monitored information as a CSV file. Refer to sec
92 (2) The setting details are monitored, and PI controller (60MC) setting screen will appear. No settings of PI Controller can be made in the Ma
933.13.3.6 Monitoring Dip switch setting of PI Controllers (1) Click [Option] in the PI controller (60MC) measurement value monitoring screen and
943.13.3.8 Pulse unit (weight) change history (1) Click [Option] in the PI controller (60MC) measurement value monitoring screen and select [Pul
953.13.4 Interlock control settings on DIDO Controllers (66DC) DIDO Controllers (PAC-YG66DCA) can control the following items of M-NET devices or the
963.13.4.1 Starting the interlock control settings on DIDO Controllers The password is needed to make the settings for interlock control. Only the al
973.13.4.2 Interlock control settings on DIDO Controllers (1) Click [Option] in the menu bar and select [DIDO/AI/PI] -> [DIDO/AI interlock setting
98<Interlock special condition setting> [Emergency stop receive: Interlock disable] When the emergency stop command is received from G(B)-50A,
Komentarze do niniejszej Instrukcji